The JOWA Cleantoil 9000 is a critical Oil Discharge Monitoring and Control System (ODMCS) designed to ensure oil tankers comply with international maritime environmental regulations. Operating as a high-precision oil content meter, it monitors the oil concentration in bilge and ballast water before discharge overboard. Key Components of the JOWA Cleantoil 9000
The system is composed of several modular units that work together to automate monitoring and prevent illegal oil discharge:
Computer Unit: Typically installed in the cargo control room, this unit manages data from all other components, performs calculations for discharge control, and logs operations into flash memory.
Analyzing Unit: This core module contains the oil content measuring unit, a sample pump, and a pressure transmitter to monitor sample flow through the measuring cell.
Converting Unit: Located in the engine room, it translates electrical signals from the computer into the pneumatic or electrical supply signals needed to operate valves and pumps. Technical Specifications
The system is built for the demanding environment of an oil tanker: Measuring Range: 0 to 1,000 PPM.
Regulatory Compliance: Certified to meet IMO Resolution A.586(14) and MEPC.51(32).
Materials: Exposed parts are primarily made of corrosion-resistant stainless steel.
Design: Robust and compact, making it suitable for retrofitting without requiring bulky bulkhead pumps. Operation and Maintenance
The JOWA Cleantoil 9000 is noted for its user-friendly "one-button touch" operation and low maintenance requirements. Jowa ODME 2005 & Cleantrack 1000 Overview | PDF - Scribd
The JOWA CLEANTOIL 9000 manual is a technical operations document for the ship's Oil Discharge Monitoring and Control System (ODMCS). It is typically a 12-chapter manual that provides detailed instructions for meeting MARPOL regulatory requirements for oil tankers over 150 GRT. Core Manual Contents jowa cleantoil 9000 manual pdf
System Components: Technical descriptions of the computer unit (data logging), analyzing unit (measuring cell and sample pump), and the Zener barrier unit.
Operational Procedures: Step-by-step guides for start-up checks, such as verifying sample probe valves, air supply (~6 bar), and overboard discharge pumps.
Maintenance & Calibration: Instructions for manual cleaning of the measuring cell, alarm resetting (e.g., for abnormal sample pressure), and calibration procedures.
Installation & Technical Specs: Detailed diagrams and wiring requirements for integrating the system into the ship’s cargo control room. Where to Find the PDF
Full versions of the manual are available on technical document hosting platforms: Operations and Technical Manual (Scribd) System Test Procedures (Scribd) Technical Overview (Hamaya-Sys) JOWA CLEANTOIL 9000 Manual | PDF | Valve | Pump - Scribd
JOWA CLEANTOIL 9000 is an Oil Discharge Monitoring Equipment (ODME) system designed to ensure maritime compliance with MARPOL regulations for tankers over 150 GRT. 5.imimg.com Manual & Documentation Resources
You can access the full technical and operational documentation through the following sources: Official Operations Manual
: Provides 12 chapters covering installation, maintenance, and technical specifications. JOWA CLEANTOIL 9000 Manual (Scribd) Technical Manual PDF (Scribd) Calibration & Troubleshooting : Specialized guides for system setup and error resolution. Calibration Guide Alarm & Discharge Procedures Core System Components
The system is divided into three primary functional units to ensure safety and accuracy: Computer Unit
: Located in the cargo control room, it processes data, controls other components, and stores discharge logs in flash memory. Converting Unit
: Typically installed in the engine room, it translates electrical signals from the computer into pneumatic or electrical supply for hardware operation. Analyzing Unit Need support
: Positioned near the sampling point, this unit contains the oil content measuring cell, sample pump, and fresh water valve for self-cleaning. Key Technical Specifications Measuring Range : 0 – 1000 PPM. Compliance : Certified under IMO Resolution A.586(14) and MEPC.51(32). Input Signals
: Accepts speed log pulses (45-999 pulses/nm) and flow meter data (4-20 mA). Self-Cleaning
: Features a unique design that minimizes the need for manual sensor cleaning. Standard Alarm Troubleshooting Common operational alarms include: Alarm Work Pressure
: Triggered when sample water pressure in the analyzing unit is abnormal (e.g., ~1.01 bar); requires checking sample tube valves. Alarm Cleaning Pressure
: Indicates a water supply shut-off or low pressure (limit typically 4.00 bar). Alarm Flow Min Limit
: Occurs during low flow or hardware errors in the sampling line. spare parts list for this model? JOWA CLEANTOIL 9000 Manual | PDF | Valve | Pump - Scribd
The JOWA CLEANTOIL 9000 is an Oil Discharge Monitoring and Control System (ODMCS) that ensures oil tankers comply with MARPOL environmental regulations by monitoring the oil content of overboard discharges Available Manuals and Resources You can find the technical and operations manual for the Cleantoil 9000 through the following resources: Operations & Technical Manual
: A 122-page document covering introduction, general description, operations, maintenance, installation, and spare parts is available on Direct PDF Download
: A dedicated technical manual for the Oil Content Meter can be downloaded via Ship Care Service Test & Calibration Procedures
: Documents detailing alarm procedures and calibration steps for the Cleantoil 9000 system are hosted on Scribd's Test Procedures Calibration Guide Official Product Page
: For the latest information on ODMCS systems, including the newer ODME 2005 model, visit the Jowa Official Website System Components & Purpose The JOWA Cleantoil 9000 is a critical Oil
The manual typically outlines the main components of the monitoring system: Analyzing Unit
: Contains the oil content measuring unit, sample pump, and fresh water valve for cleaning. Computer Unit
: Usually installed in the cargo control room to process data and store discharge logs. Zener Barrier Unit
The manual typically begins with an introduction to the system's core technology. The Cleantoil 9000 utilizes a combination of gravity separation and coalescence stages to treat bilge water.
A: Section 5.2 of the manual explains: Green zone (0-3 Bar) = OK. Yellow zone (3-5 Bar) = Change filter soon. Red zone (>5 Bar) = Change filter immediately. If the gauge hits 6 Bar, the bypass valve opens, sending dirty oil downstream.
The Jowa Cleantoil 9000 manual PDF is more than a booklet of buttons and diagrams; it is the operational blueprint that prevents downtime, accidents, and expensive repairs. Whether you are filtering transformer oil in a substation or cleaning hydraulic fluid on a lumber mill floor, the manual ensures you get 10,000 hours of reliable service.
Next Steps:
Stay clean, stay efficient, and always filter with the manual in hand.
Disclaimer: This article is for informational purposes. Always refer to the official Jowa Cleantoil 9000 manual for your specific serial number, as features may vary by production year.
The Jowa Cleantoil 9000 manual PDF includes a section on disposal. Used oil filters are considered hazardous waste in most jurisdictions (EPA 40 CFR 279 in the US). The manual specifies how to drain filters (crush or hot-drain for 12 hours) before recycling the steel casing.
Keep a printed copy of the manual near the work cell for OSHA inspections. A missing manual can lead to a citation for "lack of equipment specific safety data."
Once you get the manual, look for these critical parts:
Before we dive into download links, let’s address why the PDF manual is indispensable. While the Cleantoil 9000 is designed for user-friendly operation, it is still a complex piece of industrial machinery.