Siemens.mc.drives.acx.model.configuration Data.package Container 【PC BEST】
| Issue | Prevention |
|-------|-------------|
| Firmware mismatch | Always embed required FW version inside the package |
| Missing motor data | Validate that p0300 and p0304–p0311 are present |
| Communication loss after download | Include the PROFINET device name & IP within the package |
Traditional drive backups were limited to parameter lists or memory card images. With the siemens.mc.drives.acx.model.configuration data.package container, you can integrate drive configuration directly into your PLC project’s version control system (e.g., Git, Siemens Version Control Interface). The container stores the entire “as commissioned” state, allowing point-in-time recovery of complex motion systems.
If you export the container to an exchange format (e.g., using TIA Portal’s “Export drive as AML”), you’ll find a structured XML file. Below is a simplified representation:
<Container id="siemens.mc.drives.acx.model.configuration">
<Header>
<Vendor>siemens</Vendor>
<DriveType>Sinamics S120</DriveType>
<Firmware>V5.2</Firmware>
</Header>
<ConfigurationData>
<Parameter name="p1082" value="1500.0" unit="rpm"/>
<Parameter name="p1120" value="2.0" unit="s"/>
<Telegram type="SIEMENS_TELEGRAM_105" pzd_config="4/4"/>
<Safety submodule="F-DI" F_CRC="0x8A3F"/>
</ConfigurationData>
<Dependencies>
<Requires>siemens.mc.drives.acx.model.deviceproxy</Requires>
<Requires>siemens.mc.drives.acx.model.safety</Requires>
</Dependencies>
</Container>
Notice that the container does not store live diagnostic data (e.g., motor temperature, actual torque). It stores the blueprint—the intended configuration.
Problem: A packaging line drive fails. The replacement drive is a newer hardware revision.
Solution using the data package:
Result: Downtime reduced from 2 hours to 15 minutes.
The siemens.mc.drives.acx.model.configuration.data.package container is the structured digital vault for all configuration data within the SINAMICS drive family, aligned with the ACX (Automation Component eXchange) model. | Issue | Prevention | |-------|-------------| | Firmware
Think of it as the DNA of your drive’s parameterization – from motor data and encoder settings to application-specific control loops.
Think of this container as a virtual filing cabinet for your drive. When you add a Sinamics drive to TIA Portal or Startdrive, you aren't manually typing in every parameter (p0001, p0970...). Instead, TIA Portal opens this container.
Inside, you will find:
If you ever see siemens.mc.drives.acx.model.configuration data.package container in a log or file path, think of it as a snapshot of a drive’s "soul" – self-describing, cryptographically verifiable, and deployable offline. Its most powerful feature is enabling identical, repeatable drive configuration across thousands of axes with automated consistency checking.
The identifier Siemens.MC.Drives.Acx.Model.ConfigurationData.PackageContainer refers to a specific internal software component within the Siemens TIA Portal environment. It is typically associated with the SINAMICS Startdrive or SINUMERIK MC toolboxes, which provide the necessary configuration data for motion control (MC) drives.
If you encounter an error stating this package is missing, follow these steps to resolve it and configure your drive: 1. Install or Update SINAMICS Startdrive Traditional drive backups were limited to parameter lists
This package is often bundled with SINAMICS Startdrive, the TIA Portal engineering tool used for integrating drives into the automation environment.
Check Versioning: Ensure your Startdrive version (e.g., V17, V18, or V19) matches the version of TIA Portal you are running.
Download Updates: Missing packages are frequently resolved by installing the latest updates or "Service Packs" for Startdrive from the Siemens Industry Online Support (SIOS). 2. Verify SINUMERIK MC Toolbox
If you are working with SINUMERIK systems, this specific Acx.Model data is often included in the SINUMERIK MC STEP 7 Toolbox.
Verify if the project was created using a specific SINUMERIK version (e.g., V17 Update 12).
You must install the corresponding toolbox to enable the hardware configuration data for those specific drive models. 3. Use the "Check Updates" Tool Notice that the container does not store live
TIA Portal includes a built-in update tool that can automatically detect missing software packages required for your project.
Open the Siemens TIA Administrator or the Totally Integrated Automation UPDATER.
Scan for available updates specifically for "Motion Control" and "Drives" components. 4. Re-import Drive Configuration
If the package is installed but the error persists, the configuration data container might be corrupted within the project.
Detect Hardware: Use the "Detect" feature in TIA Portal to re-scan the connected drive on the Profinet network, which can sometimes re-establish the link to the local configuration data.
GSD/GSDML Files: For third-party integration or specific firmware versions, ensure you have imported the latest GSDML files for the SINAMICS drive into the TIA Portal hardware catalog. Required Software - Siemens SiePortal

.