Sucosoft-s30-s316 【FHD】

The product is registered as an NSF H1 lubricant. This means the ingredients are strictly limited to those defined in the U.S. Code of Federal Regulations (Title 21) for incidental food contact. While it is not intended to be added to food, trace amounts (up to specified limits) that might accidentally drip onto food products are considered non-toxic and safe for human consumption.

If you are new to the software, follow this workflow:

Sucosoft-s30-s316 is more than a legacy PLC programming tool—it is a testament to Lenze’s engineering excellence in motion control. For engineers maintaining high-speed packaging lines, converting machinery, or CNC-like systems, mastering this software means keeping production running reliably year after year.

While the industry shifts to IoT-connected, cloud-ready platforms, the deterministic, real-time capabilities of S316 remain unmatched for its target hardware. Whether you are troubleshooting a “License missing” error or designing a complex 10-axis cam profile, understanding the depth of Sucosoft-s30-s316 will pay dividends in uptime and performance.


Need further assistance?

Last updated: 2025

If you're looking for an interesting essay on this topic, here’s a structured angle you could explore:


While classified as a food-safe lubricant, Sucosoft S30-S316 contains a solvent carrier (typically aliphatic hydrocarbons).

For engineers evaluating Sucosoft-s30-s316, here are the critical technical details:

| Feature | Specification | | :--- | :--- | | Target Hardware | Lenze 3200 C (e.g., 3200 C, 3230 C, 3240 C) | | Supported Drive Series | Lenze 9300, 9400, i700, and 8400 (via system bus) | | Programming Languages | LD, FBD, ST, IL, SFC (IEC 61131-3) | | Motion Control | Up to 64 axes, 8 simultaneous interpolation channels (S316 only) | | Communication Protocols | CANopen (System Bus), CAN (Local Bus), Ethernet TCP/IP, PROFIBUS, EtherCAT (with gateway) | | Cycle Time | Down to 1 ms (position control loop), 250 µs (fast I/O) | | Runtime License | Requires hardware dongle (specific to S316 features) | | Operating System | Windows 7, 10 (32/64-bit), Windows 11 (compatibility mode) |


Product Type: Soft Starter (Motor Control Center Component) Brand Context: (Assumed to be part of a motor control lineup – e.g., similar to Siemens SIRIUS or Eaton S811 series, but drafted generically for Sucosoft).

Looking for a reliable, budget-friendly solution for your small business or home office? The Sucosoft S30 (and its upgraded S316 variant) pack solid performance and practical features into a compact, user-friendly package.

Key highlights:

Who it’s best for:

Quick buying tips:

Want a short social-media caption or a longer product post (e.g., Facebook, LinkedIn, or a product page) tailored to a specific audience? Tell me which tone and platform and I’ll draft it.

(related search suggestions provided)

Sucosoft S30-S316 is the legacy MS-DOS-based programming software for Klockner Moeller PS306 and PS316 PLCs. This software is essential for maintaining older automation systems that haven't been migrated to modern platforms like the Eaton XC series. Core Capabilities The software allows you to manage the entire lifecycle of a Go to product viewer dialog for this item. Go to product viewer dialog for this item. controller program:

Multi-Language Support: Program in Ladder Diagram (LD), Instruction List (IL), or Function Block Language (FBL).

Online Monitoring: Connect to a running PLC to view real-time status and perform live diagnostics.

Program Transfers: Upload existing logic from a PLC to a PC for backup or download new configurations to the controller. Setup & Hardware Requirements

Because this is DOS-based software, modern hardware often requires specific configurations: Sucosoft-s30-s316

Operating System: Originally designed for MS-DOS 3.3 or higher. On modern machines, it is best run via a virtual machine (like VirtualBox) using Windows 98 or directly through a dedicated legacy PC.

Interface Converter: Communication requires a specialized RS232-to-RS485 converter. The official part is the ZB4-501-UM1, though third-party options like those from Omega UK may work if they support the Suconet K protocol.

Serial Settings: For stable communication, use the following MS-DOS MODE command:MODE COM1: 9600,N,8,1,P Critical Limitations

Original Code Dependency: To go "online" and modify logic, the code on your PC must be a byte-for-byte match with the compiled code on the PLC. If you don't have the original .spj or .prj files, you cannot easily decompile the PLC's machine code into readable Ladder logic.

Migration: While Sucosoft S40 (the Windows-based successor) can often import S30 projects, it frequently triggers syntax errors that require manual correction based on Moeller Programming Manuals. Recovery Resources

If you are dealing with a program loss, you can find legacy documentation and software through authorized sources like KM Parts or specialized archives on PLCtalk.net.

Sucosoft S30-S316 is a legacy programming software suite primarily used for configuring and programming older Klöckner-Moeller (now Eaton) Programmable Logic Controllers (PLCs), specifically the PS3 series

Since this is specialized industrial software from the 1990s, a modern "review" focuses on its reliability in maintenance environments rather than its feature set compared to modern IDEs. Technical Review: Sucosoft S30-S316 Reliability & Purpose

: The software is the essential "lifeline" for facilities still running PS3-06, PS3-16, or PS3-DC units. Its primary strength lies in its simplicity; it does exactly what it was designed to do—upload, download, and monitor logic on legacy hardware that has, in many cases, outlived its expected service life. User Interface

: By modern standards, the interface is extremely dated. It typically operates in a DOS-like environment or early Windows versions. Navigation is functional but lacks the drag-and-drop intuition found in modern suites like Eaton’s -based xSoft-Discovery. Language Support : It primarily supports Instruction List (IL) Ladder Diagram (LD)

. The instruction set is limited compared to modern IEC 61131-3 standards, requiring a "workhorse" mentality to solve complex logic problems. Compatibility Challenges : The biggest hurdle for users today is connectivity. OS Compatibility

: It rarely runs natively on Windows 10 or 11. Most technicians must use virtual machines (like DOSBox or VMware running Windows XP/7) to get it stable. Hardware Interface

: Connecting to the PLC usually requires a specific RS-232 level converter (the or similar), which can be difficult to source. Final Verdict for maintenance; for new projects.

: Small installation footprint, direct hardware control, and proven stability over decades.

: Steep learning curve for those used to modern GUIs, significant driver/compatibility issues on modern PCs, and very limited debugging tools. Recommendation

Sucosoft S30-S316 (specifically version S30-S316-GB) is a legacy DOS-based programming software package developed by Klockner Moeller (now Eaton) for configuring and programming the SUCOcontrol PS306 and PS316 series of Programmable Logic Controllers (PLCs). Key Technical Specifications Target Hardware : Primarily designed for the modular PLC families. : Historically delivered on 3.5" diskettes (1.44 MB). Interface Requirements : Connection between a PC and the PLC typically requires an interface converter (such as the ZB4-501-UM1 ) or an EPC 334.1 interface card. Programming Languages : Supports standard industrial formats including: Instruction List (IL) Ladder Diagram (LD) Function Block Language (FBL) Core Functionalities

The software provides a menu-driven interface to guide users through the PLC lifecycle: Configuration : Setting up system parameters and hardware topology. Programming

: Creating user programs using operations (actions) and operands (data points). Testing and Commissioning

: Interactive debugging and program transfer to the controller. Data Management

: Users can define "markers" (internal memory bits/bytes) and set their retentive behaviour to preserve data during power failures. Modern Compatibility and Migration

As a legacy tool, Sucosoft S30-S316 has several modern considerations: Conversion to S40 The product is registered as an NSF H1 lubricant

: Programs created in S30 (often with source extensions like ) can be imported and converted by the newer Windows-based Sucosoft S40 Operating Systems

: While originally designed for DOS, it is often run on legacy Windows versions like 95/98 or through DOS emulators. Availability : Physical copies and documentation (like the DOK 9018-GB

manual) are mostly found through specialized industrial surplus suppliers or marketplaces like

Moeller Sucosoft S30 | Automation & Control Engineering Forum 18 Apr 2002 —

Sucosoft S30-S316 is a legacy programming software suite. It was developed by Moeller (now Eaton).It is used to configure and program S30 series PLCs.Specifically, it targets the PS3 and PS316 controllers. 💻 Software Purpose Development: Create logic for modular PLC systems. Maintenance: Upload or download existing program files. Monitoring: Debug real-time data on the factory floor. Documentation: Print I/O lists and network diagrams. 🛠️ Key Technical Features

Programming Languages: Uses Instruction List (IL) and Ladder (LD).

Hardware Support: Primarily for the PS3-AC, PS3-DC, and PS316.

Interface: Requires a serial connection (RS232) for communication.

Operating System: Originally designed for MS-DOS environments. ⚠️ Modern Compatibility Issues OS Constraints: It does not run natively on Windows 10/11. Virtualization: Users often need DOSBox or a VM.

Hardware Cables: Modern PCs need a specialized USB-to-Serial converter. Legacy Status: This software is no longer actively updated. 🔌 Necessary Hardware Components PLC: A Moeller PS3 or PS316 unit. PC: A computer with a COM port or adapter. Cable: UM 1-1 or similar level-matching interface cable.

License: A valid authorization code for the S30-S316 package.

Sucosoft S30-S316 is a legacy MS-DOS based programming software suite used for Klockner-Moeller (now Eaton) PS316 and PS306 series Programmable Logic Controllers (PLCs). It is largely considered obsolete in modern industrial environments but remains critical for maintaining or decommissioning legacy systems. ⚙️ Core Technical Specifications Target Hardware: Primarily designed for the (modular rack system) and Go to product viewer dialog for this item. (compact version).

Operating Environment: Runs on MS-DOS (version 3.3 or higher). Modern users typically require emulators like DOSBox or virtual machines running Windows 98/XP to execute it.

Programming Languages: Supports Ladder Diagram (LD), Instruction List (IL/IS), and Function Block Language (FBL).

Connectivity: Requires a specialized interface converter, such as the ZB4-501-UM1, to connect a PC's serial port to the PLC. ⚠️ Critical Limitations

No Source Code Upload: A major drawback is that you cannot retrieve the original source code directly from a

PLC. If you do not have the original offline project file, you can only download the compiled machine code, which is nearly impossible to edit.

Hardware Dependency: The software was originally distributed on 3.5" floppy disks. Finding official, uncorrupted copies today often requires sourcing from third-party surplus sites like eBay.

Modern Compatibility: Users frequently report "DATA TRANSFER ERROR" when using modern USB-to-Serial adapters. Standard settings are usually 9600 baud, 8 bits, no parity, and 1 stop bit.

Moeller Sucosoft S30 | Automation & Control Engineering Forum

Sucosoft S30 is a legacy, DOS-based programming software for Klockner Moeller's PS316 and PS4-100 series PLCs. It is largely considered obsolete and is primarily used today for maintaining antiquated systems rather than new development. Key Features Need further assistance

Supported Languages: Allows programming in Instruction Set (IS), Ladder Diagram (LD), and Function Block Language (FBL).

Interactive Interface: Features a menu structure designed to guide programmers through main and sub-menus.

Multi-Function Keys: The software dynamically activates keys based on the selected operation to prevent input errors.

System Configuration: Includes a System Parameter Editor to set functions like program memory tests, cycle times, and password protection. Critical Limitations & "Pros and Cons"

Security Mechanisms: For an online connection, the program on the PC must be byte-for-byte identical to the machine code on the PLC. If they don't match exactly, the software will deny the connection.

Retrieval Challenges: There is no way to upload and retrieve original source code (ladder logic/comments) from a PS316; users can only get a compiled hex file.

Hardware Dependencies: Requires specific legacy hardware, such as an interface converter (ZB4-501-UM1) for communication.

Modern Compatibility: Because it is DOS-based, it is difficult to run on modern Windows operating systems without emulation. Verdict for Developers

Unless you are tasked with maintaining a legacy Moeller PS316 system, it is recommended to transition to Sucosoft S40. S40 is Windows-based and can directly convert older S30 programs.

Moeller Sucosoft S30 | Automation & Control Engineering Forum

Sucosoft S30-S316 is the dedicated legacy programming software package designed by Klockner Moeller (now a part of Eaton) for the PS316 and PS306 series of programmable logic controllers (PLCs). This DOS-based software environment was the industry standard for developing, compiling, and maintaining industrial automation logic before the transition to modern Windows-based suites like Sucosoft S40. Core Technical Specifications

The "S30-S316" designation specifically identifies the software version tailored for the PS316 modular rack-mounted system.

Supported Hardware: Primarily designed for the Moeller PS316 (modular) and PS306 (compact) controllers.

Operating Environment: Historically requires an MS-DOS operating system (version 3.3 or higher). Modern technicians often run it via virtual machines or DOS emulators on Windows XP or 32-bit Windows 7 systems.

Programming Languages: Supports Instruction List (IL), Ladder Diagram (LD), and Function Block Language (FBL).

Communication: Connection to the PLC is typically established through a serial link (RS-232) using an interface converter like the ZB4-501-UM1 or the UM 1.5-1 converter cable. Key Features of Sucosoft S30

Sucosoft S30 provides a complete toolset for lifecycle management of the PS316 series.

Offline Programming: Logic can be developed and compiled into machine code on a PC without a live connection to the PLC.

Online Monitoring: Once the PC and PLC code are an exact match, users can go "online" to monitor real-time data and perform diagnostic tests.

Program Decomposition: The software allows for structured programming through the use of function blocks and subroutines to simplify complex automation tasks.

Security & Matching: A critical security feature of S30 is that the source code on the programming device must match the compiled code in the PLC exactly before online modifications are permitted. Communication and Setup Requirements

To successfully connect to a PS316 using Sucosoft S30, specific hardware and settings are mandatory: PLCtalk.net sucosoft s30 software | PLCtalk - Interactive Q & A